Re:Synology Lost the Plot with Hard Drive Locking Move
by fc417fc802 on Tuesday April 22, 2025 @05:36AM
(#43760401)
How are redundancy and drive failure handled? The only capacity mix-and-match scheme I have familiarity with is btrfs.
Re:Synology Lost the Plot with Hard Drive Locking Move
by cvubrugier on Tuesday April 22, 2025 @10:23AM
(#43762563)
Synology SHR is btrfs (or ext4) on top of LVM and MD. MD is used for redundancy. LVM is used to aggregate multiple MD arrays into a volume group and to allow creating one or move volumes from that volume group.
Re:Synology Lost the Plot with Hard Drive Locking Move
by fc417fc802 on Tuesday April 22, 2025 @01:01PM
(#43764190)
Comment I responded to was using LVM on its own and I was wondering about durability. The docs seem to suggest LVM supports various software raid configurations but I'm not clear how that interacts with mixing and matching physical volumes of different sizes.
"fsadm utility checks or resizes the filesystem on a device (can be also dm-crypt encrypted device). It tries to use the same API for ext2, ext3, ext4, ReiserFS and XFS filesystem."
If using BTRFS inside the LV, and the LV "backup" is mounted at /srv/backup, tell it to use the additional space using: