Re:New Electrical Code Could Doom Most Common EV Charging
by photon_rancher on Friday January 24, 2025 @12:12PM
(#42815202)
Over 100nF of unbalanced Y-caps is needed at 60Hz/120V to see 5mA gnd current. That would be a big Y capacitor (2.2n or lower is common) and they’re usually used in a balanced configuration which would reduce it further. If a Y capacitor fails on one leg, you have a problem. If a Y capacitor fails is only present on one leg, you have a problem.
And if it’s resistive leakage, that’s almost a watt of dissipation - also huge and probably a short in a cable and potentially a fire risk.
5mA is a massive threshold for well designed devices
Re:New Electrical Code Could Doom Most Common EV Charging
by Workaccount2 on Friday January 24, 2025 @03:25PM
(#42816592)
It would be fast transients that are in the kHz to MHz and over 120V. Thats why I wonder about the sensitivity of the GCFI. Can it tolerate 5mA for 50ns?
I'll admit I don't know what kind of currents they see, but 5mA on transients wouldn't be particularly surprising. There is also the factor of how sensitive the GFCI is.