Re:Water Cooled Rooftop Solar Panels by btbuildem on Thursday August 10, 2023 @03:42PM (#37080778)
From what I've seen, solar preheaters in the northern climes tend to use antifreeze instead of water, and have an exchanger in the loop. This way they can withstand below-freezing temps overnight, and be functional in the sunshine of the day. The additional benefit here being that you potable water isn't travelling through materials that are potentially degrading in the sun.
Re:Water Cooled Rooftop Solar Panels by f-securus on Thursday August 10, 2023 @04:11PM (#37081124)
I think you would only do it for the hot water input which isn’t potable after it runs through a traditional hot water heater?
Re:Water Cooled Rooftop Solar Panels by idiotsecant on Thursday August 10, 2023 @09:34PM (#37084043)
Why isn't hot water potable?
Re:Water Cooled Rooftop Solar Panels by e2e8 on Thursday August 10, 2023 @10:54PM (#37084585)
According to the EPA: "Hot water dissolves lead more quickly than cold water and is therefore more likely to contain greater amounts of lead. Never use water from the hot water tap for drinking, cooking, or making baby formula."

The applicability of this advice is probably quite variable.

[0] https://www.epa.gov/lead/why-cant-i-use-hot-water-tap-drinki...

Re:Water Cooled Rooftop Solar Panels by eric-hu on Thursday August 10, 2023 @11:21PM (#37084748)
In addition to this, tank water heater systems include a sacrificial anode rod.

Water heater tanks include different metals in contact with the water, which creates a galvanic cell. Over time this corrodes the least noble metal. The rod is added in the design to corrode before pipes do. The rod is usually magnesium, aluminum or aluminum-zinc. It slowly but steadily leeches out the rod metal into the hot water supply.

Re:Water Cooled Rooftop Solar Panels by fbdab103 on Thursday August 10, 2023 @11:46PM (#37084884)
Serious question: do we still install lead pipes anywhere? If no, when would be the threshold year where installation started to drop off for various reasons? I have heard that pex plumbing has taken over, but I have no idea if that is only for residential, but commercial use is something else entirely.