Its possible that the Tesla simply won't charge at all if the current or voltage on the line becomes too low. In this case, it would be "plugged in" but not charging.
Edit: Lets figure it out: Range=244mi. Battery capacity=58kWh. So: 5 miles takes 1.086kWh. 10% is lost in chemical conversion so we really need 1.207kWh for those miles. We pull at a rate of 1.8kWh/h from the plug. So 600 watts or so is lost elsewhere. We know the "always on" battery cooling system alone takes around 150 watts. Its not that far fetched.
Edit: I deleted my comment below where I calculated the cost of keeping the car on standby because I don't think I made clear enough (and didn't want to type it all twice) the difference between the actual discharge rate of the battery and the amount of power required at the charger to stop it. It just seems to take a lot of power at the charge port before any gets to the battery. The battery seems to discharge at an average rate of just 30 watts, but it seems to take a much, much greater amount of power input to prevent this and failing to provide this power has dire consequences. Why?
Clearly there is about 20 times that much power available at the end of a 100 foot extension cord in a standard household outlet.
Failure modes available:
• Was not actually plugged in.
• Was unplugged then plugged back in much later, possibly unbeknownst to owner. (Someone in my household unplugs my DVR to use an outlet. Grr.)
• Was on a switched outlet. (I once bought a new drill over that. Who knew one of the duplex outlets was switched and the other not? But the new drill wasn't $40k.)
• The Tesla charger could have a cutoff where it stops charging if unable to pull X amps where X is somewhere between 7 and 15. This could be either intentional or unintentional. Brown out protection circuitry, if needed by the design, could do this. They also might fear they are setting your house on fire by dropping 800+ watts somewhere in a wall and shut off.
• Broken charger.
• Broken extension cord.
Which means you have a point. If the owner in question plugged the Tesla supplied 120v cord in to an additional 100-foot, 16 gauge cord, they might have a net loss situation on their hands.
This is probably necessary to achieve UL rating.
Additionally they quote it's happened 5 times... by an un-named service manager.
It looks like they switched from ignore/mock to attack. He's getting somewhere.
First they ignore you, then they laugh at you, then they fight you, then you win. --Gandhi
http://www.teslamotors.com/goelectric/charging
Using 120V @ 15A, you get a charge rate of +5 miles (of range) per hour. Obviously not the optimal solution, but not a net negative either. Adding a 100 foot extension cord isn't going to diminish the available current enough to result in a net negative, so either the owner had additional electrical issues, or simply failed to plug it in and is making up excuses.