Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR
by Robotbeat on Friday March 24, 2023 @03:15AM
(#35286005)
A freshly poured concrete structure with poor ventilation can go well below 400ppm.
[ Parent
| on HN ]
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR
by gambiting on Friday March 24, 2023 @03:16AM
(#35286018)
Sure, so like I said, you have a situation where a CO2 scrubber(in that case concrete) is present. If you need accurate measurement of CO2 below 400ppm and not just "it's less than 400ppm" then you need to buy a different sensor.
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR
by Robotbeat on Friday March 24, 2023 @02:29PM
(#35293494)
This is a problem if you have a fairly well-sealed greenhouse as well. The CO2 level can go below 400ppm and reduce plant productivity.
If you have a suggestion for a good but affordable CO2 sensor that can measure at or below 400ppm reliably, Iām all ears!
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR
by gambiting on Friday March 24, 2023 @02:34PM
(#35293556)
So all Sensiron sensors are tuned for minimum 400ppm, other than this one:
https://sensirion.com/products/catalog/STC31
The problem is that it gives you percentage of CO2 in air instead of ppm, it can go all the way down to 0% though. I guess there must be a way to figure out the ppm based on that? I guess?
Here's an example of a product with this sensor already integrated:
https://www.sparkfun.com/products/18385
Also I want to point out that their other sensors(SCD40 and SCD41) will actually give you a value even below 400ppm - just that their accuracy drops below that value. So it might say it's 300ppm when in reality it's 250ppm. Not sure how important it is for you.