Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR by alwayslikethis on Thursday March 23, 2023 @11:35PM (#35284777)
* * *
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR by wkat4242 on Friday March 24, 2023 @04:08AM (#35286343)
Well I heard this from someone using Sensirion SCD30/31s in implementations for industrial purposes. In my own application I use them at home only and I often have a chance to air them.

What you need to do though is specifically turn off the auto calibration. Because if you don't, it will view any near-400 readings as '400' (e.g. thinking it's outside air) and the calibration is dragging itself off over time.

The MH-Z19 is a bit cheaper and I don't really have direct experience with them, though I do have one in my Awair Lite.

Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR by ysleepy on Friday March 24, 2023 @07:02AM (#35287450)
I have a MH-Z19C and have been running it with auto-calibration disabled for over a year and it didn't drift much.

Is is possible that you have auto-cal on and the sensor is never exposed to true outside air? It uses some sort of minimum tracking to calibrate the ~400ppm point.

This is anecdata though.

Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR by wkat4242 on Friday March 24, 2023 @01:27PM (#35292505)
Exactly I'm pretty sure this is what it is. It won't drift much but you do have to turn the auto calibration off, otherwise it will grab any low CO2 moment and try to calibrate to it, drifting further off track with every calibration.