Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR
by alwayslikethis on Thursday March 23, 2023 @11:35PM
(#35284777)
* * *
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR
by wkat4242 on Friday March 24, 2023 @04:08AM
(#35286343)
Well I heard this from someone using Sensirion SCD30/31s in implementations for industrial purposes. In my own application I use them at home only and I often have a chance to air them.
What you need to do though is specifically turn off the auto calibration. Because if you don't, it will view any near-400 readings as '400' (e.g. thinking it's outside air) and the calibration is dragging itself off over time.
The MH-Z19 is a bit cheaper and I don't really have direct experience with them, though I do have one in my Awair Lite.
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR
by ysleepy on Friday March 24, 2023 @07:02AM
(#35287450)
I have a MH-Z19C and have been running it with auto-calibration disabled for over a year and it didn't drift much.
Is is possible that you have auto-cal on and the sensor is never exposed to true outside air? It uses some sort of minimum tracking to calibrate the ~400ppm point.
This is anecdata though.
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR
by wkat4242 on Friday March 24, 2023 @01:27PM
(#35292505)
Exactly I'm pretty sure this is what it is. It won't drift much but you do have to turn the auto calibration off, otherwise it will grab any low CO2 moment and try to calibrate to it, drifting further off track with every calibration.
It's probably also because no photoacoustic-based sensors have a control gas side like most NDIR sensors do have as the article does mentioned. So it's much easier to eliminate environmental factors. Temperature, pressure etc.
Also photoacoustic sensors are pretty new so the tech may improve over time.
If your scenario lets the sensor see outside air every few days both are fine, but I'd still prefer NDIR if space permits, at least for now.
Even photoacoustic sensors aren't yet at the size you can put them in a phone by the way. The VOC/"eCO2" sensors are tiny and would fit in a phone but horribly inaccurate as the article says so their results aren't very useful (unless it's the VOC - Volatile Organic Component part you're interested in). But VOC doesn't really correlate to CO2 in a closed environment. For example, spray just a bit of alcohol in a room and it'll fly up like crazy but the real CO2 level will be unchanged.