News for hackers. Stuff that matters.
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR by haram_masala on Thursday March 23, 2023 @10:38PM (#35284385)
The time plot of CO2 in the bedroom is sobering - it seems that they’re reaching levels where CO2 causes cognitive impairment.
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR by elcritch on Thursday March 23, 2023 @10:50PM (#35284446)
I could imagine that happens in many boardrooms too. ;)
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR by MBCook on Thursday March 23, 2023 @11:07PM (#35284577)
It doesn’t look like it hits 1000 ppm. I thought anything under 1000 was fine and concern didn’t start until closer to 1500.
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR by gambiting on Friday March 24, 2023 @02:52AM (#35285851)
My office at home will quickly go over 2000 and then 3000ppm if I keep the door and window closed. It sucks in winter because I basically have to keep the window open(and be cold) if I want to have the privacy of a closed door.

It did make me realize why I was feeling sleepy and not quite so focused after long period of time in that room, so getting a CO2 sensor was great in that sense. I also stopped closing the door to our bedroom - CO2 levels would easily go over 2500ppm overnight if you left the door closed.

Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR by mschuster91 on Friday March 24, 2023 @03:16AM (#35286012)
If you own your home, you could install a ventilation system with an air-to-air heat exchanger with the outside... that way you at least reduce the heating loss. Or you install a forced ventilation towards whatever adjacent room there is, with a foam mesh to pad down on sounds.
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR by gambiting on Friday March 24, 2023 @03:47AM (#35286207)
We wallet has involuntarily clenched at the thought of how much that would cost. I'll stick with opening the window for now I think.
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR by mschuster91 on Friday March 24, 2023 @04:08AM (#35286344)
Why? You can have a simple indoor exchange for under a hundred dollars - a simple bathroom fan for 20€ would be a starter if you don't mind its noise, but stuff like axial fans for pot growers is pretty cheap as well (e.g. [1]). That, a 100mm core drill and a fairly simple mechanical 230V switch on the door should be enough.

A heat exchange fan can be had for 525€ [2].

[1] https://www.grow-shop24.de/Silent-Axialluefter-100m-h-100mm-...

[2] https://raumluft-shop.de/getair-smartfan-dezentraler-wohnrau...

Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR by gambiting on Friday March 24, 2023 @05:31AM (#35286880)
Because labour is crazy and I don't feel comfortable doing this myself. I've recently had a basic AC unit installed at home, it was £500 for the hardware and then another £1000 on top of that for the installation. I imagine that exchange fan would be at least £1000 installed and I just don't have a grand laying around spare to do this.
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR by mschuster91 on Friday March 24, 2023 @08:16AM (#35288018)
Yeah, AC units do require a lot of specialized labor to install (in some jurisdictions, it actually may even be mandated by law)... but a simple fan? That's half an hour for the drill, half an hour for the electrician and that's it.