A good designer will not oversize HVAC for edge cases like a once-a-decade weather system. You will size it to meet typical conditions, saving money and increasing efficiency by having a 4 ton heat pump vs 6.
For heating conditions, the typical workaround to meet demand in edge case extreme or long term cold is to add resistive heat pumps, which are much cheaper than upsizing the whole system. Though they are less efficient and therefore cost more to operate, they will only be used a few days a year when the heat pump loses ground.
I have a 60kBtu/h ground-source heat pump backed up by 7kW heat strips that replaced a 110kBtu/h gas furnace. The heat pump meets our needs for probably 51 weeks a year. Typically we will have the strips kick on during a few days in February. But it saves us a ton of money not having to have a second heat pump or larger ground loop system.
No, it's not. The temperature at which the heat pump produces zero net energy flow is a thermodynamic property of the system. You can make the system as big as you want and it will still produce zero energy, because zero times anything is still zero. That's why that temperature isn't interesting: yes, your heat pump "won't work" below that temperature, but it also "won't work" at a range of higher temperatures. And that range, as you point out, depends on installation details and insulation. But that's not what the upthread comment was saying.
And as it happens, I got a chance to measure that for my system. And it turns out to be somewhere around 15-17F. I genuinely thought folks would like to hear about that as useful info, but instead it turned into this giant "actually" subthread...
It is true that a given insulated structure will have heat loss varying based on the differential between indoor and outdoor conditions. This is a power curve, i.e. a certain kW rate of energy loss for given conditions. The rate will increase as inside and outside conditions diverge. But for anticipated conditions, it is a finite value you can use to plan your system.
This is what people mean is "just sizing": Install a system with a sufficient kW output rating to support your desired indoor and outdoor operating conditions. You would size it to exceed the real loss rate of the structure, so that you have head room to increase the differential within an acceptable recovery period.
There are heat pumps that do well below freezing, they're just top of the line and so more expensive.
The 1:1 threshold tells you about the temp that everyone needs to start thinking about alternative heat sources. If you system is undersized and/or your house is poorly insulated, that threshold may be higher, but those numbers are per installation and don't answer the broad question about if heat pumps can "work" in cold climates.
I'm deeply sorry if this offended you for some reason, but I still don't see how you're disagreeing with anything I wrote.
I did not read it that way at all. To me they are clearly talking about the point at which your heat pump no longer provides a efficiency gain over a purely resistive heater.
I think where you went wrong is reading "gain" as "heat gain" rather than "efficiency gain". While the usage of "gain" is sort of ambiguous there, the rest of the comment thread makes it clear that the term 1:1 is not discussing the point at which your heat pump stops producing any heat but the point at which it becomes inefficient.
> that's not the threshold you use to size a heat pump as is doesn't reflect a steady state
I don't think anyone except you was talking about sizing the system, but about selecting the system type given the climate.
If you had come into this just saying "here's my relevant experience with sizing heat pumps", that would have been productive. However you strongly asserted that the OP was using the wrong metric, which they weren't.
> I'm deeply sorry if this offended you for some reason,
I'm not sure why you think I am offended.
Relative and Absolute temps can generally mess people up too.
From the book Humble Pi by Matt Parker:
"In September 2016 the BBC news reported that both the US and China had signed up to the Paris Agreement on climate change, summarizing the agreement like this: "countries agreed to cut emissions enough to keep the global average rise in temperatures below 2°C (36°F)." The mistake here is not just that the BBC is still giving temperatures in Fahrenheit but that a change of 2°C is not the same as a change of 36°F, even though a temperature of 2°C is the same as 36°F. If you were outside on a day when the temperature was 2°C and you looked at a Fahrenheit thermometer, it would indeed read 36°F. But if the temperature then increased by 2°C, it would go up only by 3.6°F. The crazy thing is, the BBC initially got it correct. Thanks to the amazing website newssniffer.co.uk, which automatically tracks all changes in online news articles, we can see the chaos in the BBC newsroom as a series of numerical edits. To be fair, the article was part of the live coverage of breaking news and was designed to be regularly updated. The first version of the article that mentioned temperature gave the change as 2°C."
(https://books.google.ca/books?id=2IeVDwAAQBAJ&lpg=PT223&ots=...)
Both over- and undersizing them each have their own issues; see §2.1.1 and §2.1.2:
* https://yukon.ca/sites/yukon.ca/files/emr/emr-air-source-hea...
I overbought for sure, as I got a hybrid system that has a gas furnace backup. I've never needed it, but I've had a couple times where I wanted it and it was nice to have. If I switch it from "Heat" to "Emergency Heat", then it overrides the automatic determination of which heat source to use and just uses gas.
I didn't lose power during that cold snap, but if I did, it would have probably brought the temp back up in under 4 hours.
FWIW: we installed a heat pump recently here in Portland, and conveniently had a once-in-a-decade cold snap (17-20F for 3 days -- the PNW isn't that cold) in its second month. The system was just-barely-heat-flow-positive. A six hour power outage dropped the house temperature to ~64F, and it took a good 30 hours to get back to the 69F set point of the thermostat.
So... on the whole we're pleased and the system did just fine in extremis. But no way would it handle -20C/-4F.