Re:Microsoft's underwater data centre resurfaces after two y... by crazygringo on Monday September 14, 2020 @05:46PM (#24475511)
Heat is awfully hard to transfer in the first place, especially when it's not even that hot. It's handy if you can put your data center underneath a swimming pool, for example. But I'm not aware of any large-scale heat recovery projects from data centers. Data centers generally spend extra energy to remove the heat...

But honestly who cares if your power comes from renewables in the first place -- solar and wind? It doesn't seem right to even frame it as "wasting" heat in the first place, anymore than the sun's heat was being "wasted" warming up the ocean in the first place.

Re:Microsoft's underwater data centre resurfaces after two y... by jarvist on Monday September 14, 2020 @06:14PM (#24475754)
The new LUMI EU supercomputer in Finland will put its waste heat into a district heating system: https://www.hpcwire.com/off-the-wire/csc-lumi-supercomputer-...

I'm sure smaller scale data centre heat to district heating schemes must already be in place. Fundamentally you are using the same technology to cool the data centre (a heat pump), just pushing that heat into hot-water / steam, rather than dumping into the air.

Re:Microsoft's underwater data centre resurfaces after two y... by htgb on Monday September 14, 2020 @08:54PM (#24476819)
This has been active in Stockholm for years, at least:

https://www.opendistrictheating.com/

Re:Microsoft's underwater data centre resurfaces after two y... by Bystroushaak on Tuesday September 15, 2020 @06:49AM (#24479762)
Also Wedos here in Czech republic; https://www.wedos.org/en/
Re:Microsoft's underwater data centre resurfaces after two y... by ADefenestrator on Tuesday September 22, 2020 @09:55PM (#24562153)
It's a bit hard when the temperature deltas are so small, though. It probably works well if you're pre-heating air before the main heat source in a very cold region, but otherwise you'd need to use some sort of heat pump to get it to move around.
Re:Microsoft's underwater data centre resurfaces after two y... by Dahoon on Monday September 14, 2020 @05:58PM (#24475612)
There are towns in Denmark getting heat from Google and Facebook datacenters so I don't see why it shouldn't work elsewhere. The way MS does it here the heat is 100% waste and should be taxed like other waste. Not to mention what about the noise? The sea is already noise polluted.

Here's a source (in Danish). Wind energy in -> 25 MW/h of heat out (to heat up 12.000 houses):

https://www.computerworld.dk/art/252732/facebook-vores-data-...

Re:Microsoft's underwater data centre resurfaces after two y... by smabie on Monday September 14, 2020 @07:48PM (#24476444)
You want to tax unused heat? Are you serious?
Re:Microsoft's underwater data centre resurfaces after two y... by seventhtiger on Tuesday September 15, 2020 @02:17AM (#24478368)
If entropy continues to be an issue taxation and regulations are sensible solutions.
Re:Microsoft's underwater data centre resurfaces after two y... by nomel on Monday September 14, 2020 @06:59PM (#24476108)
If the power is generated from waves, wouldn't the energy would have gone to waste at the shoreline/breaker anyways?
Re:Microsoft's underwater data centre resurfaces after two y... by Aachen on Tuesday September 15, 2020 @04:35AM (#24479081)
> I'm not aware of any large-scale heat recovery projects from data centers.

I don't know what you'd call large-scale, but the school I went to was entirely heated by the datacenter across the road and the DC still had plenty of heat to spare. Afaik they heat all of Science Park Amsterdam with the Equinix DC just to the east: https://osm.org/go/0E6VOVkQc-. I think it was a requirement of the local government that this waste product be reused. Amsterdam has also had a datacenter stop due to power supply issues.

Edit: this seems to be the press release (only source I could find): https://www.equinix.com/newsroom/press-releases/pr/122801/eq... "Third data center in amsterdam" matches that this DC is called Equinix AM3, and it says "Excess heat from the data center will be used to warm nearby buildings and for other third-party uses."

Not to say that this happens with all the data centers across the world, but if using a decent chunk of a DC's waste heat isn't a large-scale heat recovery project, then I'm not sure what would be.

Re:Microsoft's underwater data centre resurfaces after two y... by augusto-moura on Monday September 14, 2020 @07:04PM (#24476148)
Well, you could put a sterling engine to transfer the heat to the ocean and generate energy back. This is exactly what some submarines do [1]

[1] https://en.wikipedia.org/wiki/Applications_of_the_Stirling_e...