by Cyphase on Monday August 10, 2020 @07:50PM
(#24115620)
Your last paragraph reminded me of the datacenter that famously rode out Hurricane Katrina: https://www.wired.com/2005/11/hurricane-heroics/
The blog where they posted regular updates is still up; here's the first post related to the storm: https://interdictor.livejournal.com/2005/08/27/
"Hmm. This could actually be a nasty storm."
Re:That UPS you bought for your home server may not be as us...
by jasonjayr on Monday August 10, 2020 @11:28PM
(#24116897)
That blog is an amazing insight into internet operations + culture from that time frame. Windows Media for streaming! URLS with perl/script.pl in them! AIM/ICQ! It helps the writer has a bit of a flair for storytelling.
Very good read!
Re:That UPS you bought for your home server may not be as us...
by mulmen on Tuesday August 11, 2020 @04:16AM
(#24118278)
Just getting around to really reading this. The bit rot is incredible.
Re:That UPS you bought for your home server may not be as us...
by mulmen on Monday August 10, 2020 @08:12PM
(#24115794)
I’ve never heard this story, thanks for sharing!
Re:That UPS you bought for your home server may not be as us...
by Fogest on Monday August 10, 2020 @03:48PM
(#24113261)
Working in a 911 call center this is how it worked for us. Except we had larger UPS's that could last probably 30-60 minutes in the building and then a large external generator in a small building beside. You'd see stuff like the lights that weren't on the UPS's turn off for a few seconds before the main generator fired up.
Re:That UPS you bought for your home server may not be as us...
by mark-r on Monday August 10, 2020 @06:24PM
(#24114778)
My current job refuses to replace old UPSs that have died, because they have a generator to keep the building powered in case of loss of power. But that doesn't keep your PC running for the moments it takes the generator to spin up.
Re:That UPS you bought for your home server may not be as us...
by Fogest on Monday August 10, 2020 @07:17PM
(#24115308)
Oh yeah, if we had that where we worked people would definitely be in danger. Most likely all of our systems would be down if we didn't have the UPS+Generator setup. It often takes 5-30 seconds for the generator to kick in and be running at full capacity. Normally 5 seconds, but sometimes there is a bit of a delay.
Re:That UPS you bought for your home server may not be as us...
by mark-r on Thursday August 13, 2020 @10:35PM
(#24152577)
The other part of the equation is that they're recommending that everybody switch to laptops, which are capable of running for a long time without power. My job involves a lot of long compiles, so I want to stick with a desktop PC to get the maximum compile speed.
Re:That UPS you bought for your home server may not be as us...
by Fogest on Thursday August 13, 2020 @11:08PM
(#24152817)
Considering how old the software we used was it definitely could run well on a laptop. However it does mean you have to manage the battery life on a lot of different laptops versus one central area.
Re:That UPS you bought for your home server may not be as us...
by mark-r on Friday August 14, 2020 @11:45PM
(#24165730)
Don't get me wrong, the company pushes laptops for reasons other than eliminating UPSs. Even a nearly dead laptop battery should tide you over for the minute it takes for the building generator to get online. I don't think managing laptop batteries is a big concern for our IT department.
Re:That UPS you bought for your home server may not be as us...
by linsomniac on Monday August 10, 2020 @04:49PM
(#24113822)
Everything involved in 911 calls had special tagging to indicate it. Failure to go through appropriate review and approval processes before doing work on tagged equipment would create a Resume Generation Event.
Re:That UPS you bought for your home server may not be as us...
by Scoundreller on Monday August 10, 2020 @10:09PM
(#24116517)
Nowadays, some hospitals, especially those with heating loads, are doing the opposite:
Run a combined-cycle natural gas generator 24/7, and use the grid as your backup. Gets good efficiency. Runs loops on the coolant, oil and exhaust for water/building heat, and can switch over instantly in the event of failure.
https://www.solidwastemag.com/feature/talking-bout-cogenerat...
Re:That UPS you bought for your home server may not be as us...
by dn3500 on Monday August 10, 2020 @10:00PM
(#24116472)
WWII submarine generators produced DC, so they couldn't have been used directly as backup power for a hospital. Maybe they were refitted with alternators.
Re:That UPS you bought for your home server may not be as us...
by userbinator on Monday August 10, 2020 @11:18PM
(#24116838)
I wouldn't be surprised if it was the engines that were from the WWII era.
Years later I had a tech support job in that hospital and all the PCs had small UPSs to keep them alive for the 30-60 seconds it took the big generators to come online.
I never did get a chance to see the generator room.
e: Another personal anecdote that is more relevant to the topic.
I was working for a VOIP provider back when Hurricane Sandy hit NYC. Part of our production network was housed in a telecom building in Manhattan. We received daily updates on how many floors the flooding was from our equipment and about the fuel deliveries to the building backup generators. Apparently the generators were on the roof? I'd love to know more about the setup in that building because we had zero downtime.