Re:North American versus European distribution systems (2011)
by zajio1am on Monday August 26, 2019 @09:22AM
(#20799641)
Even if the stove is powered by single phase [1], it may not be used with a 240V plug, as these are rated for 16 A. And 3.7 kW limit is enough ony for small portable 2-plate stoves.
[1] which is possible even for full 11 kW stove, if you have 40A single phase power.
Re:North American versus European distribution systems (2011)
by fyfy18 on Monday August 26, 2019 @03:39PM
(#20802960)
Bosch (and I assume Siemens and Neff which are the same company) induction hobs are limited electronically. There is a setting that lets you configure the max power it can draw from 1000W - maximum (7400W for this model):
https://media3.bosch-home.com/Documents/bosch.html?matNumber... see "Basic Settings"
I imagine that the same stove models are sold all over Europe, but that in countries where multiple phases are uncommon, the stove would come with a 240V plug already connected (i.e. set up to use a single phase).