Erm no.
1. In case the neutral gets disconnected, so the frame isn't at the potential of the hot (no voltage drop across the device)
2. So the return voltage drop in the white wire isn't on the body of the device. ~20 volts between adjacent high-current appliances on different phases probably wouldn't be terribly dangerous to most people, but it is sloppy.
3. For GFCI/RCD, it separates bona fide return currents from "accidental" return currents. With only two wires, dropping a toaster into a (PVC-drain) bathtub wouldn't trip. (Erm, I just realized most toasters are actually only two wires. Well uh, don't do that).
The geometry of the electric field in water should probably be similar to that in air (mostly contained to within the case), just don't drop both a toaster and a waffle maker in at separate ends.
It assumes that any dangerous shocking current will be taking a path that isn't just coming back on its own white wire, presumably from taking an unspecified path to ground. This seems a reasonable assumption for safety (and the NFPA surely has looked at the data), but it doesn't really inform the above isolated-bathtub situation.
By having a separate ground, it's harder to mess that up, and devices can connect the body of the device to that.
Inside the electrical box (mains) the neutral and ground are connected together, and are at the same potential.
The only reason they run separate wires is in case of of mistakes.