Re:On whether changes in bedroom CO2 levels affect sleep qua... by SketchySeaBeast on Monday January 21, 2019 @05:21PM (#18964179)
Until you get to below zero.
Re:On whether changes in bedroom CO2 levels affect sleep qua... by jrockway on Monday January 21, 2019 @06:09PM (#18964495)
I don't think that's quite true. The efficiency merely falls to 100%. (The laws of thermodynamics demand it.)

Now, converting electricity to heat may not be as cheap as converting, say, natural gas to heat (thus making the heat pump un-economical when not pumping any heat)... but you do get heat out of it.

Re:On whether changes in bedroom CO2 levels affect sleep qua... by SketchySeaBeast on Monday January 21, 2019 @06:17PM (#18964552)
That's true. But heat pumps don't have the gross energy capability as a gas heater. To get the equivalent of an 85,000 BTU gas furnace you'd need to be pumping 25 kW through your heat pump at that point.
Re:On whether changes in bedroom CO2 levels affect sleep qua... by titanomachy on Monday January 21, 2019 @06:47PM (#18964732)
I think one reason heat pumps have become more practical is that homes are now better insulated, making 85kBTUs of heating capacity excessive for all but the largest houses.
Re:On whether changes in bedroom CO2 levels affect sleep qua... by SketchySeaBeast on Monday January 21, 2019 @08:40PM (#18965286)
We've got an old, poorly insulated home which is why our requirement is so high.

The average is 30 BTU / 1000 sq feet. That's 10 kW / 1,000.

Re:On whether changes in bedroom CO2 levels affect sleep qua... by lincolnq on Monday January 21, 2019 @05:33PM (#18964273)
They now (as of 2018 I think) make Extra Low Temp heat pumps, which can work down to -15F. I think that makes heat pumps practical for a very wide variety of temperate climates.
Re:On whether changes in bedroom CO2 levels affect sleep qua... by SketchySeaBeast on Monday January 21, 2019 @06:00PM (#18964440)
I see they do, but their BTU's are very low - I see the Fujitsu RLS3H, which goes down to -26C only outputs 12,000 BTU at that temperature. To heat a house at that temperature you'd need 5-10 (if not more) of those.
Re:On whether changes in bedroom CO2 levels affect sleep qua... by golem14 on Monday January 21, 2019 @09:52PM (#18965633)
Only if you insist on the same duty cycle. Furnace might only run 4h/day, while heat pump could run all day (6* reduction)