Re:Successful second round of fusion experiments with Wendel...
by semi-extrinsic on Monday November 26, 2018 @12:00PM
(#18534732)
Not really. For power generation as in a coal or nuclear fusion or fission powerplant, you run a multi-stage steam turbine cycle to get down to as low a temperature as possible after the final LP turbine. Because that maximizes the Carnot efficiency of the (idealised) Rankine cycle, it also maximizes real world efficiency.
In practice, coing down to ~40 C (~100F) is not uncommon. And then the waste heat is basically unusable, even for district heating.
OTOH, if you need lots of heat (maybe you have a chemical plant or something nearby), you can design you powerplant for cogeneration of heat and power, yielding higher total system efficiency. But you don't do that "just" for district heating.
Yes, for district heating.