As a structural engineer on the west coast, I can say that neither of these are standard. Tuned mass dampers (TMDs) are commonly used for reducing wind-induced vibration, but not for seismic applications. Nor have I ever designed, seen, or heard of 'dynamic elements in the foundation'
The reason you can't rely on TMDs is because they are tuned to a structure's elastic period of vibration. That is to say, the materials are still in their elastic range. When a ductile structure is subjected to a sufficiently large earthquake, elements of the seismic force resisting system (SFRS) will yield. Hence the period will elongate. Hence the damper will be detuned and may not provide any benefit at all.
2) From what I understand, China has a completely different design philosophy. They design structures to remain elastic, under certain earthquakes, which would then allow for TMDs.
It's likely because you're implying "dynamic" is a "buzzword" in a discussion about structural engineering and seismic movements (which is, by definition, a dynamic system).
Also I don't really think there's a background you can have where you don't understand, or cannot lookup, the difference between dynamic and static if you really cared to understand. Seems more like self-important rhetoric than anything.