News for hackers. Stuff that matters.
Re:Scotland’s floating wind farm is showing how powerful off... by anovikov on Sunday March 04, 2018 @09:43AM (#16514845)
Solar 27% capacity factor is BS, that isn't possible. Theoretical maximum for 100% perfect weather on equator is 29%. I doubt it crosses 22-23% anywhere in the world and definitely no more than 15-16% U.S. average.
Re:Scotland’s floating wind farm is showing how powerful off... by danmaz74 on Sunday March 04, 2018 @11:15AM (#16515186)
A couple of actual numbers:

* For example, Agua Caliente Solar Project, located in Arizona near the 33rd parallel and awarded for its excellence in renewable energy has a nameplate capacity of 290 MW and an actual average annual production of 740 GWh/year. Its capacity factor is thus: 29%

* A significantly lower capacity factor is achieved by Lauingen Energy Park located in Bavaria, near the 49th parallel. With a nameplate capacity of 25.7 MW and an actual average annual production of 26.98 GWh/year it has a capacity factor of 12.0%.

https://en.wikipedia.org/wiki/Capacity_factor#Photovoltaic_p...

Re:Scotland’s floating wind farm is showing how powerful off... by Jedd on Sunday March 04, 2018 @11:20AM (#16515223)
> Solar 27% capacity factor is BS, that isn't possible.

I often gripe about people using the word nuclear to describe exclusively fission, which is regrettable for those of us keen on encouraging research in fusion.

The use of the word 'solar' to describe exclusively PVCs is comparably regrettable.

Solar thermal is pretty much guaranteed to trump PVCs at the moment, albeit at a higher capex.

Re:Scotland’s floating wind farm is showing how powerful off... by anovikov on Sunday March 04, 2018 @12:49PM (#16515596)
True, solar thermal using steerable mirrors, can do it.
Re:Scotland’s floating wind farm is showing how powerful off... by lucideer on Sunday March 04, 2018 @10:10AM (#16514914)
Are you talking about capacity or capacity factor?

From the article:

> Capacity factor measures a generation unit's actual output against its theoretical maximum output.

So this would be a percentage of your theoretical maximum, never exceeding it, by definition.

Re:Scotland’s floating wind farm is showing how powerful off... by anovikov on Sunday March 04, 2018 @10:13AM (#16514923)
I mean that, a solar panel can't produce 27 watts on average having a 100 watts peak power. In any practical location on Earth - while somewhere in the middle of Sahara desert, it will be close to that (unless you take in account solar panel's reduced power in higher temperatures).
Re:Scotland’s floating wind farm is showing how powerful off... by cjalmeida on Sunday March 04, 2018 @01:41PM (#16515862)
The denominator is based on standard test conditions. Check the link for details.

http://sinovoltaics.com/learning-center/quality/standard-tes...

Those conditions reflect not the theoretical maximum but an expected output in very good actual conditions.

This is relevant because it relates to the needed transmission capacity one need installed. For instance, at 30% capacity factor, you're "wasting 70%" of transmission on average.

It's a good metric to compare between sites of a same energy source but it's not very useful between sources. For that, the better metric is Levelized Cost of Energy (LCOE) in $/MWh. Usually present with or without subsidies.

Re:Scotland’s floating wind farm is showing how powerful off... by lucideer on Sunday March 04, 2018 @10:23AM (#16514964)
How is the 100 watts calculated in your example?

I would've presumed the theoretical maximum for a producing unit would be what it could theoretically actually produce in the location its placed. If it's the theoretical maximum output of a cell, then calling BS seems warranted, but it doesn't seem like that would be a useful comparator in this context.

Re:Scotland’s floating wind farm is showing how powerful off... by scythe on Sunday March 04, 2018 @11:17AM (#16515208)
Temperature doesn't affect capacity factor by this definition, because it reduces the numerator and the denominator by the same proportion.
Re:Scotland’s floating wind farm is showing how powerful off... by maxerickson on Sunday March 04, 2018 @10:28AM (#16514983)
https://www.eia.gov/electricity/monthly/pdf/technotes.pdf discusses their methodology some. They aren't simply using nameplate capacity as the denominator.
Re:Scotland’s floating wind farm is showing how powerful off... by eisa01 on Sunday March 04, 2018 @02:29PM (#16516118)
You can oversize the system by installing more modules behind the inverter. Hence when you calculate the capacity factor in AC terms it is higher than in the nameplate DC terms