IANAEE but would it be possible to use a DC compressor and rectify the mains, instead of using an AC compressor and inverting the PV?
[ Parent
| on HN ]
Re:Tesla deployed over 300 Powerwalls in Hawaiian schools to...
by walrus01 on Saturday February 24, 2018 @08:40AM
(#16453206)
You theoretically could, but then you would have a special weird setup that doesn't match 99.9% of the similar installation base of air conditioners on the same island. Making repairs, maintenance and such very costly. You generally want to generate usable AC power from any significant sort of solar system, so that you can use it for more than just air conditioners.
Re:Tesla deployed over 300 Powerwalls in Hawaiian schools to...
by sitharus on Saturday February 24, 2018 @08:01AM
(#16453080)
Yes, but 3-phase AC motors require less maintenance and are more efficient than brushed DC motors. Most traction applications are now using AC motors with inverters instead of DC.
Re:Tesla deployed over 300 Powerwalls in Hawaiian schools to...
by lostapathy on Saturday February 24, 2018 @09:52AM
(#16453450)
Powerwalls only output single phase AC, not 3-phase.
Brushless DC motors actually have an awful lot in common with 3 phase motors, though, in terms of operating characteristics and performance.