Re:Electronic meters’ false readings up to six times higher ... by the_mitsuhiko on Sunday March 05, 2017 @03:36AM (#13795118)
That sounds very unlikely. I would love a source for that. How do you hook up a cooker then without combining two phases?
Re:Electronic meters’ false readings up to six times higher ... by rleigh on Sunday March 05, 2017 @06:13AM (#13795498)
All the places I've lived in (UK) used a 32A 240V radial spur with a dedicated breaker with the appliance hardwired, or a regular wall socket on the kitchen ring main, 13A 240V, with a shared breaker (lower power portable appliance). Never seen 2-phase wiring for domestic use.
Re:Electronic meters’ false readings up to six times higher ... by DanBC on Sunday March 05, 2017 @08:11AM (#13795861)
I thought, but I could be wrong, that UK cookers use a radial spur with a dedicated breaker, and that sometimes those breakers also include a standard regular wall socket, but this socket (and the cooker) are still on their own radial spur.

The cooker should never be connected to a normal kitchen ring main.

Re:Electronic meters’ false readings up to six times higher ... by DanBC on Sunday March 05, 2017 @03:19PM (#13798320)
http://www.electricalsafetyfirst.org.uk/electrical-professio...

> Q1.18 Appendix 15 of BS 7671: 2008 gives advice on ring final circuits and sharing/spreading the load around the circuit. Item (iii) suggests that cookers, ovens and hobs over 2 kW should be on their own dedicated circuit. Why can’t ovens of less than 3 kW be connected to a ring final circuit via a suitable connection point such as a socket-outlet or fused connection unit?

> Appendix 15 is intended to give guidance only. Such connection is not prohibited, provided that no part of the ring final circuit will be overloaded as a result.

> Regulation number(s)

> 433.1.5

So, not forbidden, but if you have new wiring the electrician is going to give the cooker its own circuit.

Re:Electronic meters’ false readings up to six times higher ... by rleigh on Sunday March 05, 2017 @06:43PM (#13799615)
Just checked in my new-ish flat where I have an electric oven only (gas hob). It's a 13A square pin standard wall socket, but does have a dedicated breaker, so it is indeed not on the ring main for the other wall sockets. It has a 32A MCB in the consumer unit (same as on the two main rings). Not sure if it's ring or radial without removing the socket.
Re:Electronic meters’ false readings up to six times higher ... by algesten on Sunday March 05, 2017 @04:21AM (#13795195)
One phase is the standard in UK and Spain too. You don't get the same amount of Watts outs of a hob wired with one phase, and most hobs seem to be possible to wire either way.

I'm trying to google a diagram, but I only find a bunch of forum posts that explain. For Neff stuff (the one we have), the connectors are numbered 1, 2, 3, 4 and 5.

1-2-3 would be separate phases in a 3-phase home and joined together for a single phase.

https://www.diynot.com/diy/threads/neff-hob-t1-k40x2-wiring-...

Re:Electronic meters’ false readings up to six times higher ... by the_mitsuhiko on Sunday March 05, 2017 @05:12AM (#13795355)
I know nothing about spain but the UK is the exception to all rules, particularly electricity wise. It evennused to have its own color coding and circuit design.
Re:Electronic meters’ false readings up to six times higher ... by KaiserPro on Sunday March 05, 2017 @03:46AM (#13795135)
we have 220 volts in europe, we don't need to combine phases to get decent wattage with out having to install bus-bars
Re:Electronic meters’ false readings up to six times higher ... by the_mitsuhiko on Sunday March 05, 2017 @04:51AM (#13795286)
I am from Europe and here (Austria) you definitely need to hook it up with two phases and we get 230V at a 16A breaker.
Re:Electronic meters’ false readings up to six times higher ... by irixusr on Sunday March 05, 2017 @01:31PM (#13797563)
Why can't you have a one (two w/ 180 deg) phase cooker?