http://www.electricalsafetyfirst.org.uk/electrical-professio...
> Q1.18 Appendix 15 of BS 7671: 2008 gives advice on ring final circuits and sharing/spreading the load around the circuit. Item (iii) suggests that cookers, ovens and hobs over 2 kW should be on their own dedicated circuit. Why can’t ovens of less than 3 kW be connected to a ring final circuit via a suitable connection point such as a socket-outlet or fused connection unit?
> Appendix 15 is intended to give guidance only. Such connection is not prohibited, provided that no part of the ring final circuit will be overloaded as a result.
> Regulation number(s)
> 433.1.5
So, not forbidden, but if you have new wiring the electrician is going to give the cooker its own circuit.
Re:Electronic meters’ false readings up to six times higher ...
by rleigh on Sunday March 05, 2017 @06:43PM
(#13799615)
Just checked in my new-ish flat where I have an electric oven only (gas hob). It's a 13A square pin standard wall socket, but does have a dedicated breaker, so it is indeed not on the ring main for the other wall sockets. It has a 32A MCB in the consumer unit (same as on the two main rings). Not sure if it's ring or radial without removing the socket.
The cooker should never be connected to a normal kitchen ring main.