Yes talk to telco Engineers from the power side of the biz and they will have war stories about accidents and close misses with the Central Offices (Exchanges) DC power.
High Voltage/Amperage DC is quiet different to AC power and i suspect that building/wiring codes are going to need to be updated if this local storage takes off.
Re:Tesla Energy
by iamthepieman on Friday May 01, 2015 @09:12AM
(#9471011)
dropped a wrench across the terminals on the deep cycle backup batteries inside a telco switching center. Had to disconnect the whole bank of batteries to fix it because the wrench welded itself to the terminals. it wasn't a tack weld either.
Re:Tesla Energy
by mauricemir on Tuesday May 05, 2015 @04:44AM
(#9491468)
The one I remember is decorators placing a paint tin across the bus bars - which explosively painted the walls
Re:Tesla Energy
by gregpilling on Friday May 01, 2015 @03:51PM
(#9474065)
That makes for a very exciting day.
Solar systems are generally HVDC off the panel. I think in practice you'd tie the three sources (grid, panels, battery) together in the AC domain with a computer monitoring consumption and generation then signalling the battery system to charge or discharge.
Re:Tesla Energy
by raverbashing on Friday May 01, 2015 @05:37AM
(#9470335)
Yes, it would be interesting to know if there's an advantage of connecting so many cells in series
Most systems limit themselves to something like 48v as you said (I think 48v is the threshold of "being dangerous")
Higher voltage means lower current and thus lower voltage loss, and lower percentage losses for the same voltage loss, so you don’t need lots of copper.
Re:Tesla Energy
by raverbashing on Friday May 01, 2015 @09:27AM
(#9471102)
Yes, but you're throwing it into an inverter, and it's not like you're carrying it too far. High voltages also present problems in itself (isolation, etc)
Now, on a second thought, maybe it's more efficient to do 400VDC to 120VAC/240VAC (don't know the exact values)
DC-DC buck converters may be a little simpler and more efficient than boost converters, I don't really know.
Re:Tesla Energy
by patrickg_zill on Friday May 01, 2015 @05:06AM
(#9470231)
48V is under the threshold at which electrical shocks become dangerous. 48V or less is "low voltage" class. And, 48V is a multiple of both 12V and 1.5V (most individual battery cells are 1.5V), making it much easier to hook up by using a combo of parallel and series connections.
Lithium Ion also has quite a different (and much less forgiving!) charging cycle that requires much more monitoring of things like temperature, though I'd imagine a lot of that would be built-in as a safety mechanism directly into the Powerwall.
What I've heard is that National Electrical Code becomes much more stringent on battery systems greater than 48V, with the line drawn at 48V due to it being used widely in the phone landline system. I'm not sure how true that story is, but I'd imagine extra care is probably warranted. 10kWh is about 9kg of TNT. :-)