Re:Are Christmas Lights in Series or Parallel? by chillacy on Monday December 15, 2014 @05:24PM (#8754841)
Probably to save wire, if you hooked em up in parallel you'd need to send a wire to every bulb from the outlet.

With 10 bulbs at 1 inch spacing, you're wiring 1 + 2 + 3 + ... + 9 + 10 = 55 inches of wire instead of 10

Follows a roughly N^2 law

Re:Are Christmas Lights in Series or Parallel? by vonmoltke on Monday December 15, 2014 @05:32PM (#8754887)
It requires 20 inches of wire in both cases. When connected in parallel, each socket acts as a pass-through to connect the hot and grounded wires to the next socket in the set, in addition to providing power to the bulb. Thus, the sockets are in series but the bulbs are in parallel. This is how electrical wall outlets are wired.

The problem is that a parallel connection requires bulbs that can take 120VAC directly. This is not a problem with C7 and C9 light sets (the small Edison base bulbs). The minis, though, can only take a few volts. Thus, they need to be series-connected to get the voltage drops across the individual bulbs to the level a single bulb can handle.

Re:Are Christmas Lights in Series or Parallel? by Sharlin on Monday December 15, 2014 @05:53PM (#8754970)
Or you could use a transformer.
Re:Are Christmas Lights in Series or Parallel? by vonmoltke on Monday December 15, 2014 @05:56PM (#8754979)
Sure, and some sets did. It doubles the cost of a basic light set, though, so they were usually only found in the higher-end sets.
Re:Are Christmas Lights in Series or Parallel? by sliverstorm on Monday December 15, 2014 @05:50PM (#8754953)
These days you'd think they could throw a regulator in the wall plug for a few cents to get around the voltage issue.
Re:Are Christmas Lights in Series or Parallel? by munificent on Monday December 15, 2014 @06:12PM (#8755037)
That doesn't work as well when you want to string together multiple strands end to end.
Re:Are Christmas Lights in Series or Parallel? by raldi on Monday December 15, 2014 @05:28PM (#8754863)
Why would you need a separate wire for each bulb? Seems to me like you could have a ladder topology: two bus wires running from the outlet, and then the bulbs going between them.
Re:Are Christmas Lights in Series or Parallel? by chillacy on Monday December 15, 2014 @07:48PM (#8755371)
You're right, I don't know why I thought the way I did back there
Re:Are Christmas Lights in Series or Parallel? by LeoPanthera on Monday December 15, 2014 @05:27PM (#8754856)
Huh? Why not just use two wires and connect one wire to the other with each bulb.

Like this: http://www.planetchristmas.com/Images/MinisA.gif

I think the real answer is that if you did it this way (in traditional pre-transformer light sets), each bulb would have to be rated for 120v, or whatever your local line voltage is, which would make them both more expensive, and more dangerous.

Re:Are Christmas Lights in Series or Parallel? by raldi on Monday December 15, 2014 @05:30PM (#8754878)
Interesting: That would suggest that if you let enough bulbs on a strand go out, you reach a cascading-failure threshold at some point, where the voltage across the remaining filaments is higher than their rating. And then I guess the breaker trips.
Re:Are Christmas Lights in Series or Parallel? by vonmoltke on Monday December 15, 2014 @06:02PM (#8754998)
Yes, if you shunted enough of the bulbs in the strand you would get a cascading overvoltage down the line. It wouldn't trip a conventional breaker, though. Those bulbs can't pull enough power, even in over-voltage conditions. Might trip an Arc Fault Circuit Interrupter, though.
Re:Are Christmas Lights in Series or Parallel? by mindslight on Monday December 15, 2014 @07:08PM (#8755250)
Higher voltage on the remaining filaments really just shortens their life. So yes it's a type of cascading failure, but it's not catastrophic (each set has a fuse in the plug anyway, otherwise that 28AWG wire would function as the filament of last resort, if you get my drift).

This means you want to replace burnt out bulbs when you notice them, rather than waiting for the whole segment to go dark.

Re:Are Christmas Lights in Series or Parallel? by steadicat on Monday December 15, 2014 @10:37PM (#8755763)
That's not how parallel circuits work. The voltage is independent of how many devices are connected. That's how your wall plugs always provide 110V.

Edit: Sorry, I misread, I thought this subthread was about parallel circuits.

Re:Are Christmas Lights in Series or Parallel? by raldi on Monday December 15, 2014 @10:54PM (#8755792)
It's not a parallel circuit. It's a series circuit. If you have 100 bulbs in series, each is getting 1.1V across it.

If half of them burn out (and, as the article explains, become a short-circuit), then you have 50 bulbs, and each is getting 2.2V across it.

[deleted]
Re:Are Christmas Lights in Series or Parallel? by raldi on Monday December 15, 2014 @05:49PM (#8754948)
The parent comment claimed that's not the case.