Re:Boiling Sous-Vide Eggs Using Clojure's Transducers
by someengineer on Monday October 06, 2014 @11:48AM
(#8416469)
To elaborate on why you can typically avoid derivative control for thermodynamic processes:
There's no natural resonance in the system caused by energy-storing elements. For instance, if you drop a cold egg into a pot of water at exactly 80 C, it won't overshoot and go up to 85 C before settling to 80 C. Mechanical systems on the other hand often have "spring-like" behavior that causes them to resonate at certain frequencies.
If you want to get hardcore with the control design then you could look into fuzzy logic controllers. It's common in high-end appliances: http://en.wikipedia.org/wiki/Fuzzy_control_system
http://jagger.berkeley.edu/~pack/me132/Section15.pdf