The nearly 300 metres high Citigroup Center[1] in New York had a change during construction:

    original design for the "chevron" load braces used 
    welded joints. But during construction, to save labor
    and material costs, bolted joints were used instead
Which led to:

     Wind tunnel tests with models of Citigroup Center revealed the wind
     speed required to bring down the building; wind of this speed
     occurs on average once in 55 years. The building has a tuned mass
     damper, which negates much of the wind load. 

     If electric power failed, say during a hurricane, the damper would
     shut down and a much lower-speed wind would suffice; wind of this
     speed occurs on average once in 16 years.
The joints were welded in secret.