I've been in IT for 20 years so I may be jaded, but I disagree with your conclusion.
Your Levels don't seem to scratch the surface on achieving even 99.999% uptime. First of all, if you are planning on using vendors for your hypothetical 99.999% uptime you can stop there. Sure, they may promise that to you. But what is the penalty if they don't?
If you are planning on hosting this in your own data centers... Are you including diesel generators and massive diesel tanks to supply them in the event of extended power outages? What is your DDoS plan? What is your plan in the event of a hacker? What's your patching plan? These are just examples. The level of planning to achieve 99.999% uptime per year is massive. That's only 5 minutes of downtime per year!!
The bottom line is there are a handful of applications in the world that require this level of uptime. Unfortunately, every single client I have ever had was under the impression they required this level of uptime. It is my job to explain to them what reality is. If I don't, then I am not allowing them to prepare for the inevitable times that the system will be down no matter how much they spend or what they do.
http://www.datacenterknowledge.com/archives/2008/06/01/explo...
Level 1: Single server is connected to a UPS device. Domain's DNS records from multiple DNS hosting companies.
Level 2: Redundant servers load balanced on the firewall.
Level 3: Pool of redundant servers with redundant firewalls and redundant network switches.
Level 4: Geographically separated data centers with traffic routed via anycast.
Level 5: Servers in multiple datacenters from multiple distinct vendors.
Outline ballpark costs at each level plus introduce the required staffing levels to support each level including site reliability engineers to monitor and maintain each site's operation and verify correct data synchronization, 24x7 on-call engineers, equipment to enable remote diagnostics, and so on.