Re:Mercedes Bringing Tesla-Powered EV to U.S. Next Year by sbierwagen on Wednesday March 27, 2013 @07:23PM (#5452586)

  Mercedes is just as vague with battery capacity and charge 
  times, claiming the B-Class can add an additional 60 miles 
  of range in less than two hours when plugged into a 
  240-volt outlet.
"A 240-volt outlet" only provides half the information you need-- like specifying the maximum PSI of an air compressor without saying what its flow rate is. A 15 amp 240 volt outlet can only provide half as many watts as a 30 amp one.

The biggest Tesla 240-volt charger draws 100 amps = 24KW.

The Superchargers run at 440 volts and ~400 amps = 90KW.

Re:Mercedes Bringing Tesla-Powered EV to U.S. Next Year by ams6110 on Wednesday March 27, 2013 @09:14PM (#5452912)
The "smallest" 240V American household circuit would be 30A (e.g. for a clothes dryer). Electric range is 50A. I'm not aware of any common demand for 240V at only 15A.
Re:Mercedes Bringing Tesla-Powered EV to U.S. Next Year by sbierwagen on Thursday March 28, 2013 @01:19AM (#5453427)
It was an example, bro.

There actually is a standard NEMA connector for 240V 15A loads-- NEMA 6-15. It's less than common, as you'd expect.

(Running a 240V 15A circuit would be easy, all cable is rated to 600V anyway, it'd just be regular 14/2 romex. I've never actually done that, but it's possible. (Clothes dryers and ovens always use 6/3 or whatever, which will let you run 120V components off the hot-neutral circuit. 240V 14/2 would be hot-hot.))