News for hackers. Stuff that matters.
Re:Elon Musk calls NYT review of the Tesla Model S ‘fake,’ c... by masklinn on Tuesday February 12, 2013 @04:52AM (#5205993)
> I'm in Scandinavia, and our standard household circuit is 10A@230V for 2.3kW.

Only 10A? That seems very low, the common "mainland" circuits seem pretty much all rated 16A (@230V). So you can't even run some electric kettles at your place?

(but I confirm you can get 3-phase for very high loads, you'll usually pay the electricity company through the nose for running it though)

Re:Elon Musk calls NYT review of the Tesla Model S ‘fake,’ c... by j-g-faustus on Tuesday February 12, 2013 @06:22AM (#5206171)
I think the older standard was 10A circuits for most of the house, 16A for kitchen and washing room and a dedicated 20A for the electric stove. I thought 10A was the most common still, but I may be wrong there.

The standard for newer houses, the past 10-15 years or so, is indeed 16A. I have 5x16A + 1x20A and a 35A main circuit breaker, so I can pull about 8kW all together. Enough for a few kettles :) (This is for a a 40m^2/400 sq.ft. condo. A house would have more circuits and a larger main circuit breaker. And this is for Norway - we tend to follow similar standards as Denmark and Sweden, but there may be differences I'm not aware of.)

Re:Elon Musk calls NYT review of the Tesla Model S ‘fake,’ c... by masklinn on Tuesday February 12, 2013 @07:20AM (#5206322)
> I think the older standard was 10A circuits for most of the house

Ah that's probably it, I missed that you were talking about older houses. The content of your second paragraph sounds much like what I know.

Re:Elon Musk calls NYT review of the Tesla Model S ‘fake,’ c... by Tloewald on Tuesday February 12, 2013 @08:18AM (#5206567)
In Australia 240v @10A is a atandard household circuit, and dryers etc. run on 240V 15A circuits. (I believe 400V is obtainable as per the GP but I haven't lived i Australia for a while.)