News for hackers. Stuff that matters.
Re:Segway inventor's next endeavor by weaksauce on Sunday February 03, 2013 @03:08PM (#5160930)
Well you are looking at 24-48 kwh per day of use and the article says that the machine purifies ~250 gallons in that time. So approximately 10gph at 1-2kw.
Re:Segway inventor's next endeavor by beefman on Sunday February 03, 2013 @07:14PM (#5161796)
(1.5kW*24hr)/225gal ~~ 150 J/g, which is in line with the figures reported here

http://www.aquatechnology.net/vaporcompressiondistillers.htm...

Ideally, one only has to push the water back and forth over its phase boundary by an arbitrarily small delta-T, so the energy consumption can be arbitrarily small too. The 150 J/g is all heat leakage.