Re:Cooling buildings is overtaking heating them as an energy... by Aurornis on Thursday November 19, 2026 @12:34PM (#50563206)
Insulation should be a high priority, of course.

My idea was to use excess electricity generation to cool the attic somewhat below the temperature of the living space. That space would then sink some heat after the sun went down, reducing the cooling demands in the evening.

An analogous idea would be to have a large water tank in the basement with a chiller attached. You run the chiller when you have excess electricity to get the water colder than the house, then let it passively soak up heat later.

It was all shower thoughts, but the idea of storing excess energy generation during peak as coldness (wording which makes pedants cringe) for evening cooling is not new. You can pre-cool your entire house, but having to wear a sweater for a couple hours every day during the summer is not fun after a while.

Re:Cooling buildings is overtaking heating them as an energy... by bob1029 on Thursday November 19, 2026 @12:56PM (#50563500)
The water is a good idea, but the goal should be to freeze it, not simply chill it. Leveraging the latent heat of fusion makes a huge difference in system efficiency.
Re:Cooling buildings is overtaking heating them as an energy... by Aurornis on Thursday November 19, 2026 @01:29PM (#50564053)
The optimal point would be working around the efficiency sweet spot of the chiller. The colder you go, the less efficient it would be.

Freezing also introduces a lot of expansion stresses.

Having a giant ice cube in the basement would be cool, though.

Re:Cooling buildings is overtaking heating them as an energy... by SoftTalker on Thursday November 19, 2026 @02:47PM (#50565271)
This is actually done in large buildings or even at a district level for decades.
Re:Cooling buildings is overtaking heating them as an energy... by fc417fc802 on Friday November 20, 2026 @12:10AM (#50570425)
> Leveraging the latent heat of fusion makes a huge difference in system efficiency.

Only in terms of total mass required as it relates to temperature extremes (ie it makes your minima higher for a given mass). Since freezing greatly complicates things and this is already excess electricity I think you'd be better off simply adding an antifreeze and dumping all the energy you can into the heat pump. Adding additional containers of water is much cheaper than engineering to accommodate freeze/thaw cycles. You don't even need another heat exchanger you can simply circulate water between containers.