Re:Microsoft 365 outage leads to chlorine gas poisoning of 1... by wlonkly on Sunday November 15, 2026 @06:17PM (#50511930)
> reasonable amount of CYA in their pool. Even at a lowish level of 30ppm CYA

The pool in the article clearly needed more than 30 ppm, they definitely did not sufficiently cover their asses here.

Re:Microsoft 365 outage leads to chlorine gas poisoning of 1... by amluto on Sunday November 15, 2026 @08:35PM (#50512972)
lol

CYA stands for cyanuric acid, not cover your ass :) It’s added because it reversibly binds to chlorine. This causes the majority of the chlorine in the water to be in a mostly inert state in which it’s not irritating, doesn’t offgas and is protected from UV. You need very little active chlorine to control bacteria, viruses and algae, but you need considerably more chlorine to avoid the water becoming locally dechlorinated due to any sort of contamination that consumes chlorine. CYA helps fix this mismatch.