If pulling 24 amps through a TT-30 or 40 amps through a 14-50 trips a breaker, then it's the host's fault for the campground having a shoddy electrical system, not the truck driver's fault.
Re:RIP Cybertruck. You Were Unloved, Unwanted, and Utterly A... by arrowleaf on Friday November 06, 2026 @01:48PM (#50396578)
Lol in what world? Campgrounds routinely have next to no funding, if they even have power pedestals I wouldn't expect them to be wired for anything more than an RV.
Re:RIP Cybertruck. You Were Unloved, Unwanted, and Utterly A... by josephcsible on Friday November 06, 2026 @04:08PM (#50398565)
The entire reason we have so many different types of receptacles is so to keep you from plugging in something that the circuit can't handle. They shouldn't be giving people 14-50's if they don't have 50A peak and 40A continuous available.
Re:RIP Cybertruck. You Were Unloved, Unwanted, and Utterly A... by hnav on Friday November 06, 2026 @07:15PM (#50400314)
Since the whole campground went dark, presumably it was the main breaker. The branch circuit must be sized to the outlet type, but the total rating of all branch circuits usually exceeds the main breaker rating.
Re:RIP Cybertruck. You Were Unloved, Unwanted, and Utterly A... by josephcsible on Saturday November 07, 2026 @12:14AM (#50401835)
That would be a reasonable explanation if most of the campsites had people charging EVs at their max individual current, but it sounded like just one did.
Re:RIP Cybertruck. You Were Unloved, Unwanted, and Utterly A... by rootusrootus on Friday November 06, 2026 @03:04PM (#50397645)
[delayed]
Re:RIP Cybertruck. You Were Unloved, Unwanted, and Utterly A... by colejohnson66 on Friday November 06, 2026 @03:45PM (#50398260)
Is that not the point of a 50 amp socket? To say that you can draw 50 amps?
Re:RIP Cybertruck. You Were Unloved, Unwanted, and Utterly A... by rootusrootus on Friday November 06, 2026 @05:00PM (#50399078)
At the risk of saying something obvious, the socket and the breaker are sized for the peak load, not for average load. A typical home might have 300-400 amps if you total up all the breakers even though the mains are 200A or even 100A.

Also, a bog standard 14-50 is likely not suited for 80% steady EV usage anyway. They make EV-rated 14-50s now because people keep melting the older ones. And that happens even though the vast majority of chargers won't draw more than 32A on a 14-50 due to the historical popularity of using 40A breakers for a 14-50 receptacle.