Re:Elevators by tamimio on Friday July 31, 2026 @12:33PM (#49125339)
Because most buildings now they just put one button so people stop clicking both
Re:Elevators by rsanek on Friday July 31, 2026 @12:52PM (#49125653)
That has not been my experience, and logically it doesn't really make much sense. If you do so, you are making the problem strictly worse.
Re:Elevators by what on Friday July 31, 2026 @12:43PM (#49125506)
What? I’ve never seen that. The elevator needs to know which way you want to go.
Re:Elevators by allannienhuis on Friday July 31, 2026 @03:32PM (#49127593)
On the ground/lowest floor, there's only one button as there's only one way to go.
Re:Elevators by tamimio on Friday July 31, 2026 @11:22PM (#49130743)
And the top floor too
Re:Elevators by what on Saturday August 01, 2026 @12:47AM (#49131127)
That’s not what they meant…
Re:Elevators by cozzyd on Friday July 31, 2026 @04:27PM (#49128176)
i just saw this for the first time today in Romania...
Re:Elevators by userbinator on Saturday August 01, 2026 @03:51AM (#49132126)
It doesn't; it just needs to know it was called. You make your selection once it arrives.

Look up the early history of elevators and you'll see a progression from fully manual in-car up/down controls (often with a dedicated human operator); various semi-automatic systems with minor improvements like automatic leveling and door control; and then operatorless systems that started with nondirectional calls:

https://liftescalatorlibrary.org/paper_indexing/papers/00000...

Re:Elevators by Ekaros on Saturday August 01, 2026 @06:28AM (#49133041)
It is reasonable if you either have low load say a residential building where lift is often idle. Or low number of floors where travel times in either case are short.
Re:Elevators by userbinator on Friday July 31, 2026 @10:37PM (#49130566)
Nondirectional calls are mostly found in very early (pre-war) or small building (3-4 floors) installations.
Re:Elevators by userbinator on Saturday August 01, 2026 @03:51AM (#49132128)
Please see: https://liftescalatorlibrary.org/paper_indexing/papers/00000...

"2.3 Non-directional collective Non-directive collective control provides a single pushbutton at each landing. This pushbutton is pressed by passengers to register a landing call irrespective of the desired direction of travel. Thus, a lift travelling upwards, for example, and detecting a landing call in its path stops to answer the call, although it may happen that the person waiting at the landing wishes to go down. This type of control is only acceptable for short travel lifts."