Re:How a Norco case killed 13TB of our data
by mindslight on Saturday November 03, 2012 @07:31PM
(#4738264)
Those failures don't really look like moderately too much power dissipation. I'd be worried about static at the drain or counterfeit FETs. I suppose the switcher in the drives could just be drawing several amps as it's input voltage decreased and maybe those FETs don't have the best thermal resistance, but sheesh.
[ Parent
| on HN ]
Re:How a Norco case killed 13TB of our data
by mindslight on Sunday November 04, 2012 @10:44AM
(#4740028)
Oh I see, 62 K/W junction-to-ambient for an SO-8. Whereas the D2PAKs I've had desolder themselves are 1.5 K/W junction-to-case.