Re:Wiring a Generator to Your House
by Freestyler_3 on Saturday November 03, 2012 @08:58AM
(#4736496)
if your energy supplier is behind the breaker then the breaker only trips if you use all your power on other breakers. but if you use some devices on the breaker of the supplying device then that is not taken into the calculation.
I forgot to state clearly that you would be limited to the maximum of that one breaker, which is inconvenient if your usage is above it sometimes.
Re:Wiring a Generator to Your House
by mindslight on Saturday November 03, 2012 @11:36AM
(#4736814)
Doh, didn't think of that. Just goes to show how easy it is to miss something when doing things in a non-standard way, even when just tired. And emergency situations are even worse for oversights.
(Although the generators I've seen where one would be temped to use a male to male 5-15 plug have a 20A breaker on those receptacles)
You'd just end up limiting your max power to the capacity of that one circuit, and overloading would trip the breaker on the circuit you were using to backfeed. Technically if you were putting 20A into a 15A receptacle on a 20A circuit you'd be overloading it, but the same thing can happen when drawing power and such circuits are still condoned. Also technically you should only consider that circuit sufficient if you aren't planning on having a continuous load greater than 12/16A, but people generally don't pay attention to that rating either.