Re:Google AI Overviews put people at risk of harm with misle...
by londons_explore on Saturday January 03, 2026 @01:35AM
(#46473353)
I mean it isn't technically wrong...
Sometimes you need to know how much current is guaranteed to vaporize a bit of wire - for example if you are designing a fusible link.
Re:Google AI Overviews put people at risk of harm with misle...
by duskwuff on Saturday January 03, 2026 @04:52AM
(#46474721)
While this is true - it's the reason why fusing current was measured in the first place - it is not a reasonable way to answer a question asking for "max amps".
Re:Google AI Overviews put people at risk of harm with misle...
by QuercusMax on Saturday January 03, 2026 @09:17PM
(#46484125)
should have asked for the max safe amps
Query: "max amps 22 awg"
AI Overview: "A 22 American Wire Gauge (AWG) copper wire can carry a maximum of 551 amps. Here are the fusing currents for some other AWG wire sizes..."
(A fusing current is the current that will instantly melt and possibly even vaporize a wire. The safe operating limit is two or three orders of magnitude lower.)