Indoor propane furnaces exhaust outdoors in most cases. Space heaters that exhaust indoors are rare - more used for garrage heat than house. If you use them of course actount for it, but most are not.
[ Parent
| on HN ]
Re:Harnessing America's Heat Pump Moment
by Scene_Cast2 on Saturday October 25, 2025 @09:43AM
(#45703838)
Theoretically yes, in practice no. There is (according to my sensors) a fairly large CO2 increase inside a room when a modern furnace (with external exhaust) is running. I've confirmed this with several units (all made in the last 10 years), and it's not that the windows are closed - when the furnace turns off, the CO2 drops. And it's not that the exhaust is placed in a bad spot either.
Re:Harnessing America's Heat Pump Moment
by caminante on Saturday October 25, 2025 @11:23AM
(#45704605)
> There is (according to my sensors) a fairly large CO2 increase inside a room when a modern furnace
If this is happening, then you shouldn't be using that furnace/room!
Something beyond the furnace is not configured right.
Re:Harnessing America's Heat Pump Moment
by PaulDavisThe1st on Saturday October 25, 2025 @02:20PM
(#45705928)
Could also just be the furnace. Incomplete combustion conditions can give rise to the symptoms mentioned here.
Re:Harnessing America's Heat Pump Moment
by caminante on Saturday October 25, 2025 @11:46PM
(#45708983)
I doubt it's the furnace, unless there's a serial defect/recall.
The problem is likely "between the keyboard and the chair." ;-)
Re:Harnessing America's Heat Pump Moment
by PaulDavisThe1st on Sunday October 26, 2025 @12:55PM
(#45713332)
I had a gas furnace that wasn't properly maintained as far as cleaning. Result: insufficient air flow for full combustion. Secondary result: CO build up in basement space. Tertiary result: asthma-like symptoms for me.
Re:Harnessing America's Heat Pump Moment
by caminante on Sunday October 26, 2025 @02:22PM
(#45714056)
I believe it.
Re:Harnessing America's Heat Pump Moment
by thelastgallon on Saturday October 25, 2025 @02:44PM
(#45706059)
Yes, fossil fuels are the best to keep pollution away, just need to installed perfectly, configured and maintained regularly, monitored to make sure everything is running correctly, and have additional properties lying around vacant just in case there are leaks, misconfigurations, poor installation, etc. But we must use fossil fuels, there are no other options!
Your control for this test should be (and maybe was, you don't say) running the furnace circulation fan without running the burner. CO2 levels are unlikely to be uniform throughout a building, and thus mixing will change (raise, lower) the CO2 levels depending on where you're measuring.