Re:Germicidal UV could make airborne diseases as rare as tho...
by mahrain on Tuesday September 23, 2025 @07:13AM
(#45345420)
Your first paragraph is advocating for ventilation, which is great but there's been so much incentive to reduce building energy consumption (heating/cooling) that recirculating, filtration and other technologies have resulted in offices becoming almost sealed off. We are now moving towards more balanced models as people don't feel comfortable in such offices e.g. sick building syndrome.
Re:Germicidal UV could make airborne diseases as rare as tho...
by metalman on Tuesday September 23, 2025 @09:12AM
(#45346556)
my description is a bare outline, actusl instalation could easily include a heat exchanger, and by going to radiant heat, it's surfaces that provide the heat,ie: floors (warm/cool feet) and walls, cielings, with humidity controll bieng done in air
HCAC is decidedly unsexy engineering, but it can effect, all of every day so worth a bit of attention
Re:Germicidal UV could make airborne diseases as rare as tho...
by hvac_newb on Tuesday September 23, 2025 @07:17PM
(#45354062)
Since you seem to have a bit of knowledge here, are there any terms or links you would recommend for a novice to learn more about this floating concept? Really liking everything about this post
Apologies for my weak google-fu
Re:Germicidal UV could make airborne diseases as rare as tho...
by metalman on Wednesday September 24, 2025 @06:45AM
(#45358576)
The whole idea, along with complete construction techniques was given to me verbaly, and would be stumpted as to where to send you, as my local , venerable {c:1980} passive solar organisation has gone darth, and is somewhat captured by industry, though if prompted still might publish there off grid solar design manual ,which had been adopted by many other organisations worldwide.
https://solarns.ca/
The whole idea is based on thermal loops, which is powered, as everything is, by the fact that heat rises, and that internal cavitys/rooms tend to be cooler at the walls, causing a down draft there,and that energy can be put to work.
I know of other instalations in service for decades useing similar methods, but theses ideas and the floating slab are just physics. People are building houses here with double exterior walls acting as thermal breaks, which have no home heating installed, or ever needed, just air/heat exchange,normal domestic activity providing excess heat even @-25°c. Straw bale houses have proven to be the same. Luckily we have a long tradition of challenging building codes and getting engineers behind different ideas, but the full stack of passive technologies is still not bieng implimented at scale.
And then the simple expedient of useing radiant heat sources, that while not as lethal as UV, are in fact quite deadly to bacteria and anything tiny with a high water content, but completly harmless to humans and ,animals,plants. Couple this with hard, smooth ,surfaces that are designed so that there no crevices or areas filth can acumulate, useing hard woods,glass,tile,metal,leather/vinyl l,high gloss paint,for surfaces. No cloth, no carpet.While not exactly cosy or friendly, it makes getting home that much nicer. Cheap, reliable, low maintenence, implimentable at scale, now.