Re:Show HN: We built a Plug-in Home Battery for the 99.7% of...
by cantrecallmypwd on Tuesday March 11, 2025 @08:33PM
(#43338716)
As far as I know, backfeeding is illegal and not allowed by the NEC because of how dangerous it is to linepeople without a disconnect switch. A local transformer when energized by backfeed creates high voltage on lines that should be deenergized.
[ Parent
| on HN ]
Re:Show HN: We built a Plug-in Home Battery for the 99.7% of...
by borisk on Tuesday March 11, 2025 @08:38PM
(#43338754)
My guess is the battery will come with some sort of remotely controlled switch that disconnects the house from the grid, before the battery starts supplying power.
Re:Show HN: We built a Plug-in Home Battery for the 99.7% of...
by chadconway on Wednesday March 12, 2025 @12:52AM
(#43340065)
Pila can only back feed on-grid. Pila has a built in Microgrid Interconnect Device (MID). When an outage is detected, like Powerwall Pila opened the MID and continues to power downstream loads that are plugged into Pila.