Re:Gooey rubber that's slowly ruining old hard drives
by K0balt on Friday March 07, 2025 @08:29PM
(#43296671)
When the battery is removed and the pin pulled up to the 3v bus, the thermostat works flawlessly.
I traced the circuit, it goes between ground and the uC pin, through a 1 Mohm resistor, no other connection. It’s about right for killing a 300mah battery over 10 years. The pin is held low when the unit is energized by the thermostat signal lines.
I traced the circuit, it goes between ground and the uC pin, through a 1 Mohm resistor, no other connection. It’s about right for killing a 300mah battery over 10 years. The pin is held low when the unit is energized by the thermostat signal lines.