It could generate the high speed CPU clock using the 32khz clock as a reference. What I found was the layout guy ran a digital trace through the pins of the 32khz xtal. There was enough coupling that digital transitions on that line would cause the high speed clock to swing wildly. Which showed up as garbage on the UARTs. Joyous thing is most of the time that line was idle.
I cut and rerouted the trace and the problem went away.
I ended up disabling the auto cal feature during a UART reception and then turning it back on when the reception is done.
SPI is definitely better as far as clocking, but MCU support as a SPI receiver is sometimes a lot less convenient to deal with.
A lot of UARTs have a synchronous mode which adds a dedicated clock signal - I've used that before out to a couple MHz.
In this application though, I'm only running 1 MHz so I really didn't think I should need a separate clock (and, it turns out, still don't).
It's also possible that the design hasn't been thoroughly tested and the PLL doesn't lock in certain conditions which could leave you with an unstable clock.
Turning it off during a UART transaction definitely "fixes" it.
I'm somewhat tempted to do the manual calibration the HSI instead.
If you really need the accuracy then regularly time the LSE clock using a timer clocked from MSI and apply the best trim values as described in this app note file:///home/tom/Downloads/an4736-how-to-calibrate-stm32l4-series-microcontrollers-internal-rc-oscillator-stmicroelectronics-1.pdf
It sounds like the sampling clock frequency is not what is expected (but that's quite easy to check based on the transmitted signal so I'm quite confused)
UARTs are nice if you are constrained on pins but SPI is always a safer bet where you don't have the necessary high accuracy clocks.