Re:Facebook Outage: Wake Up Call For Websites
by j79 on Friday June 01, 2012 @03:38PM
(#4055283)
I was lucky enough to listen to Souders talk at Fluent this past week. He talked about Front-end SPOFs and specifically an experience in Beijing where Business Insider didn't load because of a third party widget (Twitter, in his case) being blocked.
One site he mentioned (and great for testing) was webpagetest.org.
Re:Facebook Outage: Wake Up Call For Websites
by rabidsnail on Friday June 01, 2012 @02:58PM
(#4055042)
Before you deploy, test with facebook.com and twitter.com sent to 0.0.0.0 in your hosts file. Facebook has been getting more reliable, so it's possible to develop a feature and deploy it without Facebook breaking.
Re:Facebook Outage: Wake Up Call For Websites
by duskwuff on Friday June 01, 2012 @06:40PM
(#4056232)
For this purpose, 1.1.1.1 is probably an OK IP to use for testing. It's in a range that's technically a routable public IP, but which will almost certainly never be announced (as it receives a ridiculous amount of bogus traffic).
Re:Facebook Outage: Wake Up Call For Websites
by zyce on Friday June 01, 2012 @07:04PM
(#4056313)
Internal Server Error
The server encountered an internal error or misconfiguration and was unable to complete your request.
Please contact the server administrator, [email protected] and inform them of the time the error occurred, and anything you might have done that may have caused the error.
More information about this error may be available in the server error log.
Apache/2.2.9 Server at blog.catchpoint.com Port 80
Re:Facebook Outage: Wake Up Call For Websites
by jkimmel on Friday June 01, 2012 @06:41PM
(#4056234)
The 1x1 pixel trick he mentions is a wonderful little hack. Such an elegant solution to keeping your clients' sites working without even requiring site managers' action.
One site he mentioned (and great for testing) was webpagetest.org.
Here are the slides from the talk: http://stevesouders.com/talks.php
He blogged about the issue here: http://www.stevesouders.com/blog/2012/03/28/frontend-spof-in...
You want to link it to a machine that will never reply - or worse will start to reply and then just sit there.