Re:A near 100pct renewable grid for Australia is feasible an...
by adrianN on Thursday March 28, 2024 @08:43AM
(#39850541)
If your house had problems with condensation forming on the outside then I hope it never rains where you are.
[ Parent
| on HN ]
Re:A near 100pct renewable grid for Australia is feasible an...
by throw0101b on Thursday March 28, 2024 @08:58AM
(#39850708)
Water in liquid form (e.g., rain) will (mostly!) go down with gravity, and so overhangs will help a lot, as will proper grade sloping away from your foundations.
Water in vapour form will be more diffuse and be everywhere the air is.
Further, your cladding / water control layer (which deals with rain (and UV)) generally needs to be open to air so that it can dry properly:
* https://en.wikipedia.org/wiki/Rainscreen
so that can lead to moist air getting places that water may not, and if you don't have insulation between the warm-moist outside and the cool-dry inside:
* https://buildingscience.com/documents/insights/bsi-001-the-p...
problems can start.