Heh. We tried it too. They didn’t believe that a single node used their entire rack’s budget at first.
[1]https://www.supermicro.com/en/products/system/gpu/5u/sys-521...
Also, this involves a UK university where it would takes forever to upgrade the power delivery to the building/floor/room. There's no planned upgrade whatsoever so people just need to make do with what we have.
The one data point I know well is NERSC, and has been air cooled until relatively recently. Part of the success of air cool in the past was the great Bay Area weather that is typically cooled enough. I forgot the exact reason for upgrading to water cool, but it was before the recent upgrade to a new machine (Perlmutter). It may have to do with our weather getting more extreme so that there are more incidences that air cool only will “throttle” your machine.
The reason I’m skeptical about that claim is that the ambient temperature also play a role. But certainly the density is increasing so may be the biggest supercomputers at the moment are too dense (in power consumption) to be air cooled.
- Frontier: Liquid cooled
- Aurora: liquid cooled
- Eagle: liquid cooled
- Fugaku: liquid cooled
- Lumi: Liquid cooled with heat recycling.
The need for liquid cooled arrived with the usage of accelerators that bumped significantly the power density.
That said, Fugaku which is not accelerator driven is also liquid cooled today.
I am surprised to learn that NERSC was air cooled until recently. Most of the BGQ machines, that were dominating the top500 10 years ago, were already liquid cooled.
But perhaps you're right that the physics is the ultimate factor here: what comes in must goes out. With order of magnitude scale of increase in power coming in, water seems to be the most effective and cheap entity to absorb those heat and be transported outside the floor very efficiently.
Liquid cooling is almost a defacto-standard in data centers in the HPC world. The Top of the TOP500 machines are all liquid cooled. Not by choice, but due to physics constraints.
There is a big gap in power density between the HPC world and the usual datacenter-commodity-hardware world.
Commodity DS are designed with the assumption that the average machine will run with a fraction of it's maximum load. HPC systems at the opposite are designed to operate safely at 100% load all the time.
In a previous company where I worked, we attempted to install a medium size HPC cluster in a well-known commerical datacenter and network provider. The commercial of the DS almost felt from his chair when we announced the power requirements.