I never did do the research to figure out what was up with the water, but similarly, when I tried inventing my own sump-pump sensor by dipping copper wire into the sump well, it ate the copper wires apart in 3 days. I tried again with stainless rods and discovered that there was about .05 Volt per inch deep I put the sensor, i.e. the stainless rod near the top of the well would be about 2V higher (or lower, don't recall) than the stainless rod that ran to the bottom. Made it kind of annoying to design the circuit.
If I used well water or had another non-city source, I would do my best to keep copper out of the plumbing and I would minimize brass as well. Stainless steel and plastic, please.
The subject may be more complicated than my single sentence can capture.
You won’t have the problems you would have with galvanized steel. Copper ions leached out of a copper pipe will react with zinc and non-stainless steel and can very quickly degrade under some conditions even without electrical contact. Stainless steel, not so much.
(Don’t let rainwater that came from a copper gutter or that ran over treated wood hit a galvanized steel flashing. Really, just don’t use galvanized steel flashings at all.)
Metals in a plumbing (i.e. wet) system need to be either isolated from each other or be galvanically compatible.
This applies to roofing, too. Nail the flashing down with galvanically compatible nails, or you'll find the flashing all comes loose after a couple years.
Not really?
A battery has two paired half reactions. Something gets oxidized, something gets reduced, and electrons flow through the conductive bits.
So if you have some metallic zinc, and you have some copper ions, and you have some metallic copper, and you have electrical contact, zinc will be oxidized, copper ions will be reduced and plate into the copper, and current will flow. Once the zinc is gone, if you had galvanized steel to start with, the iron will oxidize.
Now try stainless steel. The half-reaction involving the stainless steel, hmm, doesn’t involve iron — the iron is physically separated from the electrolyte by the passive layer. Chromium? Barely - a tiny bit oxidizes and then it stops. We’re left with 2H+ + 2e- -> H2. Which can happen without the stainless steel too, but with more available surface area, it’s faster.
So a lot of stainless steel will accelerate the corrosion of a small amount of copper. But the reverse has little effect.
There is apparently a real concern the with H2: some grades of stainless steel are apparently rather susceptible to hydrogen embrittlement.
You'll also find the same if you google for copper and stainless galvanic compatibility.
I tried introducing some stainless fixtures and did not have a good time with it.
I'm not a pro by any means but I do all of my own plumbing and gas work in my house. Haven't had one issue out of iron gas pipe or copper water lines. I was actually planning a pex install/replacement, and I have worked with it in my camper, but I changed my mind after doing some more work with copper recently (replaced water pressure regulator). Waaaaay cheaper than messing with pex.