Re:In-memory vs. disk-based DB: Why do you need a larger tha... by wtallis on Saturday September 02, 2023 @05:21PM (#37365632)
> even if you compare with RAID0 of high perfomance NVMe.

Do you mean a RAID0 of just two or four NVMe SSDs? It's absolutely ridiculous to count aggregate DRAM bandwidth across two CPU sockets and not do the same for PCIe lanes. A fair comparison is that Genoa has about twice the DRAM bandwidth as it has PCIe bandwidth, though in a fully-loaded database server some portion of the PCIe bandwidth will be used for networking rather than storage.

Re:In-memory vs. disk-based DB: Why do you need a larger tha... by zamadatix on Saturday September 02, 2023 @05:35PM (#37365729)
FWIW I think you have the aggregation backwards, dual socket Genoa would have 24 channels of DRAM but sacrifice some of the PCIe lanes for the interconnect.
Re:In-memory vs. disk-based DB: Why do you need a larger tha... by wtallis on Saturday September 02, 2023 @05:52PM (#37365843)
Dual-socket Genoa would be 24 channels at DDR5-4800 (38.4 GB/s) for a total of ~921.6 GB/s. Typical PCIe configurations are 64 or 80 lanes per socket for dual-socket, so 128 or 160 lanes total, at PCIe 5.0 speed that's ~504 GB/s for 128 lanes total or ~630 GB/s for 160 lane configurations.

Single-socket Genoa would be 12 channels of DRAM (~460.8 GB/s) and 128 lanes of PCIe 5.0 (~504 GB/s), but none of the previous comments were specifically about single-socket Genoa and I wasn't going to silently switch from considering dual-socket in one sentence to single-socket in the next sentence.

Re:In-memory vs. disk-based DB: Why do you need a larger tha... by zamadatix on Saturday September 02, 2023 @06:19PM (#37366010)
Ah yes, I forgot about the 48 lane 2 socket interconnect mode which does allow you to still aggregate some additional lanes.