Re:Google flushes heat from data center with toilet water by ars on Friday March 16, 2012 @02:42PM (#3714687)
This is not as green as it sounds.

This area of the united states suffers from huge water shortages, and the river they are using is a major source of water for Atlanta (I'm not sure if they are upsteam or down from Atlanta).

As a result by the time the river flows out of Georgia into Alabama and Florida it is very diminished. This makes those states pretty upset since they also want to use the water.

So what does Google do? They evaporate the water! What a waste.

Water cooling is not really a very clean thing in this part of the country.

I would like to see some numbers: How much energy does it cost to desalinate the amount of water they are wasting? If it's more than the energy they are saving then they do not have a net win.

Re:Google flushes heat from data center with toilet water by ajross on Friday March 16, 2012 @07:46PM (#3715832)
"So what does Google do? They evaporate the water! What a waste."

Quite literally a drop in the bucket. The back of my envelope has too much written on it at the moment, but if you look at the total water flow in that watershed and multiply it by the heat of vapoization of water you get a staggeringly large energy flow. There's no way; absolutely no way at all a few megawatts of server heating would be measurable at all. None.

Re:Google flushes heat from data center with toilet water by InclinedPlane on Friday March 16, 2012 @11:40PM (#3716310)
I happened to have a free envelope:

Google's total worldwide power usage is about 220 megawatts, calculate the amount of water starting at about 20 deg. C average needed to evaporate to carry away all that energy and that works out to about 700 million gallons of water needed per year. Which is about one or two days of water usage for Atlanta. Keep in mind that this is for all of google's data centers worldwide. For only the servers that are actually in Georgia the amount of water carried away is incredibly small compared to total usage.

Also I didn't account for radiative cooling which is probably fairly significant but likely not more than, say, 50% of the necessary cooling load.

Re:Google flushes heat from data center with toilet water by Retric on Friday March 16, 2012 @10:59PM (#3716253)
1 megawatt * 1 hour = 3,600,000,000 joules Water takes 2,257,000 joules / kg to evaporate Which works out to ~1,600 kg or 422 gallons of water per hour per MW.

However, I don't think they actually want to evaporate all that much water which leaves a lot of residue issues and instead focus on heating a much larger volume of water.

PS: The article is also wrong in that they don't directly cool hot air from their servers with this water. They are cooling air heated by there cooling system and depending on how hot the air from there servers are they may simply vent that if it's warmer than the outside air.

Re:Google flushes heat from data center with toilet water by ajross on Friday March 16, 2012 @11:25PM (#3716289)
Heh, the gauntlet has been thrown, so I need to show numbers too.

I see that Atlanta rainfall is about 48" (122cm) a year.

422 gallons * 24 * 365 (* 3.785 litres/gallon) * 100 cc/L == 1.4e9 cc/year.

So converting to rainfall area: 1.4e9cc/122cm = 1148 m^2

Basically a 100' square catch basin on the roof of the building would provide all the water they need. Noise.

Re:Google flushes heat from data center with toilet water by shabble on Friday March 16, 2012 @11:57PM (#3716322)
> Basically a 100' square catch basin on the roof of the building would provide all the water they need. Noise.

Which raises the question: Why don't they just do that? I'd imagine it would be less effort to process, and even though you do need to have a buffer against low rainfall periods, water is one of the easiest things to store.

Re:Google flushes heat from data center with toilet water by Retric on Saturday March 17, 2012 @10:17AM (#3717121)
O, I agree it's Noise. However, the reason they don't use a catch basin / just pay for it is Atlanta's high average humidity. There are going to be days where little water is going to evaporate in those cooling towers and most of their energy is going to simply raise the temperature of a large volume of water. So, having access to say 100 times the flow they need is vary helpful.
Re:Google flushes heat from data center with toilet water by jcampbell1 on Friday March 16, 2012 @06:44PM (#3715648)
This is an absurd argument. Evaporative cooling is green and efficient, but problematic during droughts. Your argument is like saying wind turbines are pointless because sometimes the wind doesn't blow.

If Google cools with fossil fuels during only droughts, that is still much better than using fossil fuels all the time.

Re:Google flushes heat from data center with toilet water by learc83 on Friday March 16, 2012 @06:44PM (#3715656)
>(I'm not sure if they are upsteam or down from Atlanta).

The two reservoirs which provide water for Atlanta are located far north of Douglas County (I'm a resident).

I do find it odd that they are using evaporation cooling, since humidity is so high here.

Re:Google flushes heat from data center with toilet water by shawnz on Friday March 16, 2012 @03:45PM (#3714943)
I don't really know anything about this, but how does water cooling consume water? Is it not just for heat transfer?
Re:Google flushes heat from data center with toilet water by justincormack on Friday March 16, 2012 @03:53PM (#3714977)
Not evaporative cooling.
Re:Google flushes heat from data center with toilet water by ceol on Friday March 16, 2012 @06:11PM (#3715537)
I would like to know why Google had to open a datacenter in that specific region. It gets incredibly hot and humid.
Re:Google flushes heat from data center with toilet water by jrockway on Friday March 16, 2012 @08:19PM (#3715915)
Presumably to reduce latency for nearby users. People in warm climates deserve fast Google results too! :)
Re:Google flushes heat from data center with toilet water by hendzen on Friday March 16, 2012 @09:59PM (#3716128)
The amortized CAPEX (cost of building the data center) is still greater than the OPEX (cost of keeping it running). If Google can find cheap land and labor, heat might be irrelevant.