Re:Successful room temperature ambient-pressure magnetic lev...
by jacquesm on Friday August 04, 2023 @09:00AM
(#36999359)
> Even if your ohmmeter conductors have a resistance of several ohm, you could still get an accurate measurement if your tool has a high enough resolution.
Not that low in range though, you will end up seeing thermal noise that dwarfs your measurement.
Re:Successful room temperature ambient-pressure magnetic lev...
by dclowd9901 on Friday August 04, 2023 @10:59AM
(#37000940)
How about the wires connected to your probes? Or the internal electronics that are used to gauge resistance? How do you work around those?
A bigger issue is going to be sample size. A 1mm-diameter 1mm-long rod of silver has a resistance of about 20 μΩ (or 2e-5) at room temperature. That's already getting tricky to measure with lab-grade equipment without pushing insane currents through it, let alone anything even smaller. If you want to measure a 1m-diameter 1m-long silver rod (which would be 0.02μΩ or 2e-8) you could just push a few thousand amps through it and reliably measure that using a household multimeter in the mV range - but do that with a small sample and it'll evaporate.