Re:1000W 12V –> 220V Inverter by spicyjpeg on Wednesday May 31, 2023 @06:39PM (#36145376)
> If I were making something for this problem I would make an AC-DC-AC converter with a PLL to divide the 60Hz input frequency to 50Hz to control the inverter.

This is the best way to do it, especially if the synchronous motor inside the clock is actually fed with a lower voltage from a transformer (which seems to be common in old radio clocks as they needed a transformer anyway to power the radio circuitry). If that is the case, it should be possible to bypass the transformer entirely and build a converter that operates entirely on low voltage; some quick searching suggests that this exact kind of project has already been done before in fact [1].

[1]: https://mitxela.com/projects/phase-locked_inverter

There are no comments on this comment yet.