Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR
by Malic on Friday March 24, 2023 @08:42AM
(#35288277)
A crowd-sourced map of such levels across a large geographic area (with outdoor/indoor data) would be interesting to look at.
Has anyone done something like this already?
Re:Low Cost CO2 Sensors Comparison: Photo-Acoustic vs. NDIR
by londons_explore on Friday March 24, 2023 @12:08PM
(#35291109)
CO2 data is hard to crowdsource because the sensors aren't yet built into phones, and tend to all be proprietary with no standard interface.
They could alert when CO2 goes over 1500 ppm and say 'Warning:. Harmful air quality detected. Increase ventilation or move outdoors'.
The same sensor could also detect Ozone, CO or NOx using different LED's, thereby making a pretty good detector for common poisonous gasses.