I’ve looked and don’t see any cracks in the slab, but admittedly 1/2 of the basement is carpeted and drywalled and so I don’t have a good view of it.
I use the AirThings View Plus, and note that it has been running for 2.5 months, and I want to see what it settles at as a longer term average.
Realistically, popping a hole in the slab and installing a fan might be less disruptive than tearing out all the finishing.
Do you have a sump? First, seal it. Caulk as much of the wall-floor joint as you can. If it's still not low enough, add a fan _to the sump cover_, since the weep-tile system might provide all the sub-slab vapor communication you need without adding any new holes.
However, that is almost always a rounding-error in terms of basement soil-gas infiltration. You can sometimes feel a literal breeze coming through a crack if the house is badly depressurized (windy day and stack-effect), you will never feel a breeze coming straight through a solid concrete or cinder-block wall.
The spikes probably come from depressurization events like that. Sometimes the wind is angled in such a way that the house effectively forms a whistle or a manometer, and soil gas migrates at a greater rate during those times.
This is somewhere that _passive_ sub-slab ventilation (drill a hole, connect a vent pipe to the outside, no fan) can often help significantly, along with caulking all the cracks. Seriously, don't bother with anything else until you've caulked.
What's the level you're trying to mitigate?
https://www.epa.gov/sites/default/files/2016-02/documents/20...